Campbell Hausfeld FP2400 Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Compresseurs d'air Campbell Hausfeld FP2400. Campbell Hausfeld FP2400 Operating instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Q
U
A
L
I
T
Y
A
S
S
U
R
A
N
C
E
P
R
O
G
R
A
M
Need
Assistance?
Call Us First!
1-800-543-8622
NOTE: Unit will not run when
charging.
Do not operate
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety
Since the air compressor and other
!
WARNING
5. Wear safety glasses and
use hearing protection
when operating the
pump or unit.
6. Do not stand on or use the pump or
unit as a handhold.
7. Before each use, inspect compressed
air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or
replace defective items before using.
8. Check all fasteners at frequent
intervals for proper tightness.
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
pumping system, the following safety
precautions must be observed at all
times:
1. Read all manuals included
with this product
carefully. Be thoroughly
familiar with the controls
and the proper use of the
equipment.
2. Follow all local electrical and safety
codes as well as in the US, National
Electrical Codes (NEC) and
Occupational Safety and Health Act
(OSHA).
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage! Retain instructions for future reference.
© 2004 Campbell Hausfeld/Scott Fetzer
Description
Portable cordless air compressors are
for home and workshop use. All
models are equipped with regulators,
ball bearings, and motors with
automatic overload protection.
Safety Guidelines
This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure any
loose fittings, bolts, etc., are tightened
before putting unit into service. Make
sure to install fuse promptly after
opening. Have the serial number,
model number, and parts list (with
missing parts circled) before calling for
assistance
DO NOT RETURN THE
PRODUCT TO THE
RETAILER!
NOTICE
!
CAUTION
!
WARNING
!
DANGER
Operating Instructions
IN606903AV 9/04
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
“as is” to supply breathing quality
air. For any application of air for
human consumption, the air
compressor/pump will need to be
fitted with suitable in-line safety
and alarm equipment. This
additional equipment is necessary
to properly filter and purify the air
to meet minimal specifications for
Grade D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
!
DANGER
MANUAL
BUILT TO LAST
STOP!
Cordless Air
Compressor
Record the Model No., Serial No. and
date of purchase located on the pump
in the space below.
Model No. ____________________
Serial No. ____________________
Date of purchase _________________
Retain these numbers for future
reference.
Model FP2400
For parts, product & service information
visit www.chpower.com
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
See Warranty on page 10 for important information about commercial use of this product.
Notes
Notes
Notas
32
Cordless Air Compressor
Compresseurs d’air sans fil
Compresor de aire sin cable
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Compressor

QUALITYASSURANCEPROGRAMNeedAssistance?Call Us First!1-800-543-8622NOTE: Unit will not run whencharging.Do not operate unit if damagedduring shipping,

Page 2 - Electrical Data

23 Sp10Limited Warranty1. DURATION: One year from the date of purchase by the original purchaser: One Year.2. WHO GIVES THIS WARRANTY (WARRANTOR): Cam

Page 3 - Pre-Operation

22 SpQUALITYASSURANCEPROGRAMNeedAssistance?Call Us First!1-800-543-8622NOTE : L'appareil nefonctionnera pas enchargeant.Ne faitespasfonctionner l

Page 4 - Más Cercano a Su Domicilio

12 Fr19. Ne jamais fairefonctionner lecompresseur prèsd'incendies, de gaz oude liquides inflammables.20. Ne jamais laisser l'appareil sanssu

Page 5 - Technical Service

20 Fr13 Fr120 VOLT C.A. DE CHARGEPour recharger la pile à l'aide del'adaptateur de c.a. 120 volts, suivre lesprocédures suivantes :1. Pousse

Page 6 - Modelo FP2400

19 Sp14 Frd'élimination des piles. Régulateur1.Ce régulateur contrôle la pressiond'air au boyau et aux accessoires.2. Tourner le bouton dans

Page 7 - ADVERTENCIA

18 Fr15 FrModéle FP2400EntretienDébrancher la source decourant et ensuite dégagertoute la pression du système avantd'essayer d'installer, de

Page 8

17 Fr16 FrCompresseur d'air sans filTableau de dépannageModéle FP2400Tableau de dépannage (Suite)Symptôme Causes possibles Mesure correctivenLe c

Page 9

3120. Never leave unit unattended whilein use.21. Protect the unit from rain, snow orother sources of moisture.22. Turn off power switch when not inus

Page 10 - PRECAUCION

30 Spbattery for 7 to 9 hours. If the unit isused too long after the yellow lightcomes on, recharging time couldtake up to 20 hours and the batterylif

Page 11 - Compresseur

29 SpMaintenanceDisconnect power sourceand then release allpressure from the systembefore attempting toinstall, service, relocate or perform anymainte

Page 12 - Compresor de aire

28 Sp5Model FP2400www.chpower.comMaintenance (Cont.)STORAGE1. When not in use, store hose andcompressor in a cool dry place.2. Disconnect hose and han

Page 13 - ATTENTION

27 Sp6Cordless Air Compressorwww.chpower.comTroubleshooting ChartSymptom Possible Cause(s) Corrective Action1. No electrical power to charger2. Blown

Page 14

7Model FP24001. Air consumption higher than compressoroutput2. Air leak3. Internal leak4. Defective pump1. Defective pressure switch.2. Other electric